Unused back pressure steam turbine generator 6000 KW
Stock #AS60935
Unused back pressure steam turbine generator Kaluga P6-3,4/0,5-1 with the electrical output 6 MW. Main parameters of the steam turbogenerator:
Electrical output 6000 KW.
Inlet steam 3.4 bar, 435 degrees C.
Outlet steam 0.5 bar, 225 degrees C.
Steam consumption 57.9 tons per hour.
Three phase, 50 HZ, cos 0.8.
Location: Europe
Add to Cart
View Details
1500 kW 15 Bar Kaluga Steam Turbogenerator Set
Stock #AG61861-01
Used back pressure steam turbogenerator set by Kaluga type op-1.5-3. Nominal capacity 1500 kW. Inlet stem flow pressure 15-21 bar, temperature 350*C. Back pressure 3 ATM. Size parameters - length 2961mm, width 2090mm, height 2262mm.
Location: EUROPE
Add to Cart
View Details
1500 kW 15 Bar Kaluga Steam Turbogenerator Set
Stock #AG61861-02
Used back pressure steam turbogenerator set by Kaluga type op-1.5-3. Nominal capacity 1500 kW. Inlet stem flow pressure 15-21 bar, temperature 350*C. Back pressure 3 ATM. Size parameters - length 2961mm, width 2090mm, height 2262mm.
Location: EUROPE
Add to Cart
View Details
2000 kW Belliss Turbogenerator Set
Stock #AG61842-01
Used back pressure turbogenerator set with the capacity 2 MW, turbine made by Belliss type SPB-350, new in 2003, approximate steam consumption 32 TPH, inlet steam pressure 42 kg/cm2, exhaust pressure 1/1.5 kg/cm2, 10250 rpm. Generator by Crompton Geaves, new in 2003, 2000 kW, 2500 kVA, 1500 rpm, 420 V, 3 phases, 50 Hz. Scope of supply and additional information on request.
Location: ASIA
Add to Cart
View Details
12000 kW 35 Bar Kaluga Turbogenerator Set
Stock #AG61862
Used back pressure turbogenerator set by Kaluga type P-12-35/5 with the capacity 12000 kW. Inlet steam pressure 35 bar, inlet steam temperature 435*C, back pressure 5 ATM. Steam consumption 94800 - 114700 kg/hour. Electrical power 9600-12000 kW. Additional information on request.
Location: East EUROPE
Add to Cart
View Details
12500 kW 63 Bar Power Plant
Stock #AS61917
Used power plant with the electrical capacity 12500 KW. Main equipment of the plant is following: Tube type boiler with the steam output of 63 ton/hour, 480 degrees Celsius, 63 bar. Type of burners: 2 R&V burners type TTL/MG-22.5. Fuel - Fuel Oil/ Natural Gas/ Coal. Two back pressure Siemens turbogenerators, one with the electrical output 5500KW and another one with 7000KW. More information on request.
Location: N/A
Add to Cart
View Details
16000 kW Steam Turbine Generator Set
Stock #RG9620
Used 16000 kW back pressure steam turbine generator set made 2007 and shut down December 2017. Sale includes:
- MAN Marc 4B steamturbine, made in 2008, capacity 16230kW, nominal speed 8120 rpm, fresh pressure steam 99 bar, consumed fresh steam 129.2 tons/hour, pressured finished steam 7 bar, temperature fresh steam 410 degrees Celsius, temperature used steam 165 degrees Celsius.
- Lubrication system made by Reinhold Wesselmann GmbH in 2007.
- Control oil system made by Hydac Systems GmbH in 2007.
- Gear box / transmission made by Renk AG in 2007 with nominal power 17050 kW, configured power 18650 kW, 8120 / 1500 rpm.
- Generator made by Jemont Electric in 2008 with power 16240 kW, 20300 kVA, 10500 V +/- 5%, 1116 A, 50Hz, 1500 rpm, 0.8 power factor, total hours logged 60,145.
- Fire extinguishing system made by Van Wijk en Boersma in 2008.
- Central control and operating cabinets.
- Steam characteristics at inlet of steam turbine under normal operation at max load: 99 bara, 400 degrees Celsius, max flow 129.2 tons/hour.
- Steam characteristics at exhaust at max: 7 bara, 165 degrees Celsius, 129.2 tons/hour.
Location: Europe
Add to Cart
View Details
2000 kW 24/2.5 Bar Atlas Dual Back Pressure Turbine
Stock #ZS60714
Used 2000 kW Atlas dual back pressure turbine C - 700 TE with the gearbox connected with coupling to a Skoda 1994 generator. The generator is coupled with the turbine on a steel frame. Single-stage steam turbine with an integrated gearbox. Self turbine stage is attached to the gearbox with one high-speed pinion on which is mounted the turbine impeller with two-stage axial blading type C. The cabinet is mounted on transmission. Bearing lubrication gear is protected from the oil system generator.
Rated parameters steam parameters *
input 2.4 [MPA ABS.] 350 [° C]
output 0.25 [MPA ABS.] 210 [° C]
rpm 6000/3000 [min-1]
steam consumption, performance
steam flow 30 [T.H-1]
rated power 2000 kW
generator
rated voltage:6300V, 3 phase
EL. Performance in 2500 [kW]
at the terminals of electrical generator
regulation
turbine operation ensures by electronic regulator tr 101 and Electro-hydraulic oil, low pressure unit
Voith.
By oil pressure unit is controlled regulatory quick-closing valve.
Turbine regulation allows these types of operation:
-speed control maintains the desired speed during turbine start-up, before connecting the generator to
the electric net, during the controlled shutdown after disconnecting the generator.
-backpressure-regulation the control works only when running the generator sets connected to the
electric net. Flow steam turbine is determined by immediate collection of steam appliances and electric
power corresponds to this flow (which made electrical power should be used). Pressure regulators
maintain a constant (adjustable) backpressure.
- oil management for lubrication of bearings and gearwheels of transmission:
- main gear driven oil pump which supplies pressurized oil for lubrication of turbines in operation
(gear). Approach-electric oil pump
- emergency oil pump driven by an electric motor for supplying pressure oil for lubrication and cooling
of bearings at full power failure (power supply from an Independent source such as ups).
Oil-tank has a volume of about 400 liters. For lubrication can be used turbine oil TB-46 or equivalent,
complying with IEC 65 6620.
-oil cooler (2 X plate L25 GG 60) to aggressive cooling water. Flow of water max 20 ° C is about 8.4
+5.2 T.H-1, the cooler pressure loss is about 35 KPA warming water of 8 ° C.
Required cooling water over pressure of 0.6 MPA.
For cooling is considered chemically treated water:
content of mechanical particles max ............ 50 mg.L-1
PH ................................................. ...... 7 ÷ 8.3
hardness ................................................. .. 4 to 7 mg EQ.
Content of impurities ............................. 700 to 1000 mg.L-1
it is recommended to insert to the water circuit coke filter
-two oil filters - each containing: 6X insert CFO 11942 25 microns.
Location: EUROPE
Add to Cart
View Details
2000 kW 348 PSI Atlas Dual Turbine
Stock #ZS60722F
Used Atlas model C-700TE dual turbine. New in 1986. Maintenance in 2008.
Turbine with the gearbox is connected with coupling to generator, the generator is coupled with the turbine on a steel frame. Single-stage steam turbine with an integrated gearbox. Self turbine stage is attached to the gearbox with one high-speed pinion on which is mounted the turbine impeller with two-stage axial blading type C. The cabinet is mounted on transmission. Bearing lubrication gear is protected from the oil system generator.
The nominal parameters of the turbine Atlas C - 700 TE
required quality of steam according to CSN 07 7401 allowable increase in pressure and temperature
on a quick valve according to EN 60045-1
rated parameters steam parameters *
input 2.4 [MPa ABS.] 350 [° C]
output 0.25 [MPa ABS.] 210 [° C]
rpm 6000/3000 [min-1]
steam consumption, performance
steam flow 30 [t.h-1]
rated power 2000 kW
generator
rated voltage: 3 kV x 6300
EL. Performance in 2500 [kW]
at the terminals of electrical generator
regulation
turbine operation ensures by electronic regulator tr 101 and electro-hydraulic oil, low pressure unit
Voith.
By oil pressure unit is controlled regulatory quick-closing valve.
Turbine regulation allows these types of operation:
-speed control maintains the desired speed during turbine start-up, before connecting the generator to
the electric net, during the controlled shutdown after disconnecting the generator.
-Backpressure-regulation the control works only when running the generator sets connected to the
electric net. Flow steam turbine is determined by immediate collection of steam appliances and electric
power corresponds to this flow (which made electrical power should be used). Pressure regulators
maintain a constant (adjustable) backpressure.
Oil management
oil management for lubrication of bearings and gearwheels of transmission:
- main gear driven oil pump which supplies pressurized oil for lubrication of turbines in operation
(gear). Approach-electric oil pump
- emergency oil pump driven by an electric motor for supplying pressure oil for lubrication and cooling
of bearings at full power failure (power supply from an Independent source such as ups).
Oil-tank has a volume of about 400 liters. For lubrication can be used turbine oil TB-46 or equivalent,
complying with IEC 65 6620.
-oil cooler (2 x plate L25 GG 60) to aggressive cooling water. Flow of water max 20 ° C is about 8.4
+5.2 t.h-1, the cooler pressure loss is about 35 KPA warming water of 8 ° C.
Required cooling water overpressure is 0.6 MPa.
For cooling is considered chemically treated water:
content of mechanical particles max ............ 50 mg.l-1
PH ................................................. ...... 7 ч 8.3
hardness ................................................. .. 4 to 7 mg eq.
Content of impurities ............................. 700 to 1000 mg.l-1
it is recommended to insert to the water circuit coke filter
-two oil filters - each containing: 6x insert CFO 11942 25 microns.
Location: N/A
Add to Cart
View Details
3000 kW 360 PSI Allis Chalmers Non-Condensing Steam Turbine Generator Set
Stock #ZG60118
3000 kW Allis Chalmers Non-condensing steam turbine generator set, 360 PSIG @ 670-720°F, 20-40 PSIG exhaust, 3/60/4160 V, 3600 rpm. 9 stages (1-Curtis, and 8-Rateau).
Location: Midwest USA
Add to Cart
View Details
4000 kW 40/3 ATI Kaluga Turbogenerator
Stock #ZS60234
Used 4000 kW Kaluga turbogenerator. 40/3 ATI. 450 celsius temperature. 50HZ .
Location: N/A
Add to Cart
View Details
5000 kW 395/45 PSI General Electric Non-Condensing Turbogenerator
Stock #ZS54894
Used GE non-condensing turbogenerator rated 5000 kW producing power at 3 phase 60 HZ 4160 volt. Steam conditions: inlet 395 psi, exhaust 45 psi.
Location: N/A
Add to Cart
View Details
6250 kW 600/95 PSI General Electric Steam Turbine
Stock #ZG60417
Manufacturer: General Electric
type: condensing
kW rating: 6,250 kW
inlet steam pressure, PSIG: 600 PSIG
operating temperature, ºF: 825ºF
automatic extraction, PSIG: 95 PSIG
exhaust pressure, inches of HG: 3.0” HG.
Rpm: 3600 rpm
year new: 1959
date last operated: 2006
direct connected to:
generator:
manufacturer: general electric
capacity in kVA: 7,500 kVA
power factor: 80%
frequency: 60 hertz
voltage: 2140/4160 volts
speed: 3600 rpm
cooling system: air cooled
exciter:
voltage: 125 volts
Location: South USA
Add to Cart
View Details
10,000 KW 870 PSI WEG Back Pressure Steam Turbine Generator
Stock #ZW62459
Used WEG Back Pressure Steam Turbine Generator rated at 10,000 KW, with inlet steam conditions of 60 Bar (870 PSI) and dual extraction at 14 Bar (200 PSI) and 4 Bar (60 PSI). Steam Turbine is skid mounted and Generator is rated at 6000 Volts, 50 HZ, 3 Phase.
Location: South America
Add to Cart
View Details
10000 kW 42/6 Bar Steam Turbine/Generator
Stock #ZS60722K
Used set steam turbine/generator.
Mfg : TGM
power: 10000 kVA
model : TM 15000a
year of manufacture : 2001
type : pressure
rated speed : 8000
inlet pressure : 42 bar
exhaust pressure : 6 bar
steam temperature input : 420 є C
flow inlet steam : 65 ton / H ( 5MW )
specific consumption : 13 ton / MW ( current status )
gear : PTI power/transmission Industries
reduction : 1,444
rotation of entry : 8000
power : 9470 kW
service factor : 1.37
power generator Mfg : WEG
model : SSW 800
year of manufacture : 2001
rated speed : 1800 rpm
active power: 10000 kVA
output voltage : 13,800 V
current : 418.4 a
frequency : 60 HZ
insulation class : F
Location: SA
Add to Cart
View Details
11000 kW 715/200 PSI Turbodyne Non-Condensing Steam Turbine
Stock #ZG60222
Turbodyne non-condensing steam turbine
11,000 kW, 3600 rpm, 715 PSIG in at 725 degree F, 200 PSIG exhaust.
Steam flow at full load: 375,000 lbs/hr
generator
electric machinery
13,450 kW, 15,825 kVA
13,800 volts, three phase, 60 Hz, 0.85 pf, 662 amps
shut down NOV. 1998. Still installed.
Scope of supply:
steam inlet valve.
Steam exhaust valve.
Turbine turning gear.
Turbine Lube oil system, L.O. Tank, coolers, oil filters with
controls, etc.
Location: USA
Add to Cart
View Details
12000 kW 510/75 PSI Kaluga Steam Turbine Plant
Stock #ZS61313
Reportedly unused steam turbine plant "Kaluga turbine plant". Includes turbine model P-12-3.4/0.5 made by "Kaluga turbine plant" in 1996. Steam data:inlet steam absolute pressure 3,4 MPA (510 psi)@ 435 DEGC; discharge pressure 0.5 MPA (75 psi)@ 221 DEGC; steam flow rate approx.111,24TPH. Includes generator model T-12-2UZ made by Lisva in 1996. Power data: nominal power 12000 kW, 6300V, 3000rpm, 97,65%; excitation power data 230V@268a. Weight of turbine approx.35 ton, weight of generator approx.28 ton. All on dead storage.
Location: EUROPE
Add to Cart
View Details
20700 kW 1325/475 PSI General Electric Steam Turbine Generator
Stock #ZG60772
Used 20.7 MW General Electric 8 stage back pressure steam turbine generator, manufacture year 1987, counter clockwise rotation, steam inlet 1325 psi @ 900 F, 475 psi extraction and 70 PSIG exhaust, air cooled general electric generator is rated at 3600 rpm, 13,800 volts, 3 phase, 60 HZ. Last major overhaul 10/2007 operating hours since last overhaul 10,390.
Location: USA
Add to Cart
View Details
34000 kW 800 PSI General Electric Steam Turbine Generator Set
Stock #ZG59604
Used GE 34MW back pressure steam turbine generator set with auto extraction.
Manufacturer: Canadian GE
rating: 34000 kW
inlet steam: 800 PSIG/825 deg F
max inlet steam flow: 640,000 lbs/hr
extraction steam: 150 PSIG
extraction flow: 0 to 500,000 lbs/hr
exhaust steam: 75 PSIG
exhaust flow: 0 to 500,000 lbs/hr
speed: 3600 rpm
generator:
rating: 40,000 kVA
volts: 13800V/3/60 HZ
year built: 1972
year shutdown: 2007
scope of supply:
steam turbine generator unit with all associated equipment still installed.
Location: USA
Add to Cart
View Details