Steam Turbine Generators Condensing


Steam Turbine Generators Condensing - Czech & Slovakia

Steam Turbine Generators Condensing - Europe

Used steam turbogenerator Siemens, 2,6 MW, 40 bar, 15 t/h

Used steam turbogenerator Siemens, 2,6 MW, 40 bar, 15 t/h

Stock #AS60959-01

Unused condensing steam turbogenerator Siemens KKK condensing type with continuous extraction, rated capacity is 2600 KW. Steam parameters: Inlet pressure 40 Bar, inlet temperature 400 degrees C, rated flow 15 000 kg/h, extraction pressure 6.8 bar, extraction flow 0 - 14 000 kg/h. Voltage 11000 V / 3 phase / 50 Hz / 1500 rpm. Two block condenser is included.

Location: Europe

Add to Cart View Details

Unused condensing turbogenerator with electrical output of 12 MW, 35 bar, 435 degrees celsius

Unused condensing turbogenerator with electrical output of 12 MW, 35 bar, 435 degrees celsius

Stock #AG61942

Unused condensing turbogenerator Kaluga type ПТ-12-35/10М with the capacity 12000 KW, 3000 rpm, 35 bar, 435*C, 10500 V, 50 Hz. Steam extraction up to 50 ton/hour with pressure 10 bar. Weight of the unit is approximately 35 ton. New in 1991. More information on request.

Location: Europe

Add to Cart View Details

Used condensing steam turbine generator Dresser Rand type 4QHBT2VIXI, 11,4 MW, 39.5 bar, 390 deg С

Used condensing steam turbine generator Dresser Rand type 4QHBT2VIXI, 11,4 MW, 39.5 bar, 390 deg С

Stock #AS60911

Used condensing steam turbine generator set Dresser Rand type 4QHBT2VIXI with the nominal electrical output 11400 KW. Working steam parameters: 39.5 bar, 390 deg С. Maximum steam parameters: 43 bar, 420 deg C. Steam pressure on the outlet 0.15 -0.2 bar. Generator Jemont type JISALT 412, 15000 kVA, 11000 V. Supply includes: Oil hydraulic station with the heat exchanger. Air-cooled steam condenser by Hamon with the steam pipeline and drainage units. Vacuum condenser. Cooling system. Feed pumps. Control cabinets. New controls.

Location: Europe

Add to Cart View Details

Used 3600 kW Biomass Power Plant

Used 3600 kW Biomass Power Plant

Stock #AG61890

Used 3.6 MW biomass fueled power plant. Type of fuel, wood waste with 10% moisture content. Main equipment of the plant; used KEM water tube boiler with natural circulation, steam capacity 15.5t/h, steam pressure 35bar. Steam temperature 450*C, boiler efficiency: 90.3%. Used condensing steam turbine Skoda, with power output 3580KWE, speed 12060rpm. Used generator AVK, 4500kVA, 3600kW, 6300V, 412a, 1500rpm, 50Hz. Additional information on request.

Location: Europe

Add to Cart View Details

Used 1800 KW 24.5 Bar 50Hz Siemens Condensing Turbogenerator

Used 1800 KW 24.5 Bar 50Hz Siemens Condensing Turbogenerator

Stock #AG61933

Used SIEMENS type KKK CA-36 condensing turbogenerator set with 15000 hours of operation. Designed electrical output 1800KW. Steam pressure 24.5bar, temperature 430*C, extraction steam pressure 2.1bar, condensing steam pressure 0.1bar. Steam flow 9.5ton/hour. Generator AEM type SE500 M4, Apparent power 2250kVA, 1500rpm, active power 1800KW, 400V, 50Hz. Unit is dismantled and preserved. More information on request.

Location: Europe

Add to Cart View Details

Used 1.5 MW Triveni Power Generator

Used 1.5 MW Triveni Power Generator

Stock #V850-18

Used 1.5 MW power generator by TRIVENI ENGINEERING & INDUSTRIES, Bangalore, India (supplied through Florida Chemicals & Trading Co., Miami, FL, USA) model 14A, # FR14A-135 (manufactured 1998). Turbine control panel by HAMMOND, Governor control panel by SYSPRO with WOODWARD 505 digital governor Duplex oil filter by INDUSTRIAL ENTERPRISE, type 45, # 1729 Alternator: EM BEMAC 2 Specifications:- Back pressure type, power rating 2100 BHP, hydraulic test pressure 10 psi, working pressure 6 psi, rotor/gear Speed 7200/1000 RPM, trip speed 7920/8250 RPM, inlet steam pressure/temperature 170 psig/485oF, exhaust steam pressure 15 psig The unit was completely overhauled during 2011-2012, with new electronic control systems and repairs to the rotor, and recommissioned during 2013

Location: Jamaica

Add to Cart View Details

11.4 MWel, 43.1 bar Condensing Steam Turbine

11.4 MWel, 43.1 bar Condensing Steam Turbine

Stock #RG9709

Used 11.4 MWe condensing steam turbine made by Dresser-Rand (now Siemens) including auxiliaries and air-cooled condenser. Equipment was made in 1998, shut down in 2013, dismantled and put into storage in 2016. Reportedly generally revised by the OEM, and will be delivered with new electrical cabinet and process control. Steam parameters of turbine at inlet: 43.1 bar, 390 degrees Celsius, max 59 tons/hour.

Location: Europe

Add to Cart View Details

20 MW Mitsubishi Turbogenerator with Meiden Synchronous Generator

20 MW Mitsubishi Turbogenerator with Meiden Synchronous Generator

Stock #V813-205

Used 20 MW Mitsubishi extracting / condensing turbogenerator #5. Meiden synchronous generator type ZIC-aft with output 18941 kVA, 1500 V 60 Hz could extract 425 psi to 150 psi, 1800 rpm, S/N 8N5596P1. Power factor-85%. Spares available. New 2000.

Location: HI

Add to Cart View Details

1500 kW 23 Bar Biomass Power Plant

1500 kW 23 Bar Biomass Power Plant

Stock #AG61883

Used biomass-coal power plant with the capacity 1500kW (1.5MW). Main equipment: Turbogenerator set by Kaluga П-1,5-21/5, steam consumption 10t, inlet pressure 21 bar, bleed steam outlet pressure 5 bar, operation time 10000 hours. Water tube boiler, 12.5t of steam per hour, 23bar, 350*C, operation time 11000 hours. Fuel coal and wooden chips (70%-30%). Reported that Boiler can opperate on 100% woodchips after modernisation. Additional information on request.

Location: Europe

Add to Cart View Details

2700 kW 42 bar Condensing Steam Turbine Generator Set

2700 kW 42 bar Condensing Steam Turbine Generator Set

Stock #RG9665

Used 2.7 MWe condensing steam turbine generator set made by Triveni in 2012. Currently still installed and in service with approximately 45,000 hours of use. Inlet Temp: 410 Deg C Inlet Pressure: 42 Bar Exhaust Pressure: 0.7 Bar

Location: United Kingdom

Add to Cart View Details

3540 kW 565 PSI Biomass Fueled Power Plant

3540 kW 565 PSI Biomass Fueled Power Plant

Stock #RG8896

Used 3.5 MW biomass fueled power plant reportedly made in 2004 and shut down in 2011. Includes: - 17.6 TPH biomass fuelled boiler made in 2004 , shut down in 2011. Rated 39 Bara, 390 degrees Celsius. - 3.54 MW condensing with extraction steam turbine generator set made in 2006, shut down in 2011. Apparent power 4,425 kVA, power factor 0.8, 1500 rpm, 6000 V, 50 HZ . - also includes air condensation system & electrostatic filter, pellet press, loading silo, hammer Mill. More details on request.

Location: Europe

Add to Cart View Details

5000 KW Biomass Power Plant

5000 KW Biomass Power Plant

Stock #AG61926

Used biomass cogeneration plant with electric capacity 5 MW or 5000 KW. Two Boilers with steam parameters: 45 bar, 420°C, 25 t/h (2x12.5 t/h). Fuel type: Wood chips with the moisture content above 50%. Condensing Steam turbo generator electrical output: 5 MW (MAN-Turbo). Turbine is equipped with extraction: 2.4 bar (0 -20 t/h). Air Cooled Condenser. Generator: 6.250 kVA, 6.3 kV, 50 Hz – Schorch/LDW. Emission cleaning system parameters comply with EU standards. Fuel preparation and feeding system is included as well as control room, cyclones and other auxiliary equipment. Plant has been started in 2000, operated until 2014. More information on request.

Location: Europe

Add to Cart View Details

6000 kW Biomass Fired Power Plant

6000 kW Biomass Fired Power Plant

Stock #AG61842-03

Used 6000 kW biomass fired power plant. Designed to work on bagasse from sugar cane. All equipment new in 2000. Boiler made by Thermodyne technology stem capacity 45 TPH, steam parameters; pressure 45bar, temperature 440 C. Turbine by Belliss steam consumption 44 TPH, bleed steam extraction 11 TPH, capacity 6000 kW, rpm 8500. Generator Toyo Denki Japan (by Kirloskar Ltd.), 1500 rpm, air cooled. Additional information on request.

Location: ASIA

Add to Cart View Details

6500 kW 26 Bar Siemens Turbo-Generator

6500 kW 26 Bar Siemens Turbo-Generator

Stock #AG60914

Used condensing turbo generator Siemens with the capacity 6500kw. Main parameters of the turbo generator: nominal capacity 6500kW. Steam flow 30-35 t/hour. Steam pressure 26 bar. Steam temperature 350°C. Exhaust pressure 0.25bar. Generator Siemens: Voltage 6600 V. 50 hz, 713 A, 8.150 kva, S1, cos 0.8. Gear box Renk, type and size 560, ratio 6.423, speed input 9635 rpm, output 1500 rpm.

Location: N/A

Add to Cart View Details

8600 kW 40 Bar Condensing Turbine Generator Set

8600 kW 40 Bar Condensing Turbine Generator Set

Stock #AG61864

Used condensing turbine-generator set with the power capacity 8600 kW. Steam consumption 40 ton/hour. Inlet pressure 40 bar, inlet temperature 450*C. Exhaust pressure 0.08 bar. Speed 6983 rpm. Supply includes - gearbox, 4 pass water cooled condenser, generator 11000V, 50HZ. Reported low operating hours.

Location: Europe

Add to Cart View Details

10500 kW 260 PSI AEG-Kanis Condensing Turbogenerator Set

10500 kW 260 PSI AEG-Kanis Condensing Turbogenerator Set

Stock #AG61848

Used 10.5 megawatt condensing turbogenerator set made by AEG-Kanis (Germany). Steam parameters: inlet steam flow 50.4 ton/hour. Inlet stem pressure 18 bar. Inlet steam temperature 350 degrees Celsius. Outlet steam flow 50.4 ton/hour. Outlet stem pressure 0.095 bar. Outlet steam temperature 44.8 degrees Celsius. Speed of the turbine 7100 rpm. Generator made by Voith with following parameters - 11215 kW, 50HZ, 11000 V. 1500 rpm. Condenser made by GEA 2815 M3/hour.

Location: ASIA

Add to Cart View Details

11450 kW 1146 PSI Biomass Power Plant and Condensing Steam Turbine

11450 kW 1146 PSI Biomass Power Plant and Condensing Steam Turbine

Stock #RG8892

Used 11.45 MW biomass power plant and condensing steam turbine. Reportedly made in 2001 and shut down in 2010 with approximately 70,000 hours of use. Plant is currently dismantled and in storage. Boiler is suitable for wood chips and has live steam quantity of 46 TPH, pressure 74 Bara, with maximum pressure of 85 Bara. The condensing steam turbine is rated 13.35 MW, 6804 rpm, 70 Bara, inlet flow 47.15 TPH. More details on request.

Location: N/A

Add to Cart View Details

12000 kW 82 Bar Coal Fired Power Plant

12000 kW 82 Bar Coal Fired Power Plant

Stock #AG61870

Used 12MW coal fired power plant. Plant includes a steam boiler, steam Turbogenerator set, water treatment plant, fuel handling line, operation system, ash handling system, compressors, etc. Boiler by Cethar limited type bk032, main parameters: 82 bar, 515 C*, 50 TPH, with fluidized bed combustion. Turbogenerator by Siemens type SST 300, main parameters; 12000 kW, 10800 rpm, 510C*, 84 kg/cm2.

Location: ASIA

Add to Cart View Details

15000 kW 425 PSI General Electric Turbogenerator Condensing

15000 kW 425 PSI General Electric Turbogenerator Condensing

Stock #V813-204

Used General Electric (GE) 15000 kW steam turbine-generator Extracting/condensing unit #4. Turbine (no.197858): rating - 15000 kW 3600 rpm, 13 stages, steam CONDITIONS -425PSIG, temperature-740F, exhaust pressure-3,00HG.ABS. Generator air cooled (no.316X400) 2 poles, 3 phase WYE CONN., 60 hertz rating - 24500 kVA, Armature amps-1,025, Armature volts - 13800, field amps-203, excitation volts - 250, power factor - 0,80 inlet water -95F. Generator was under major overhauling in January 2016. Spare parts available.

Location: Western USA

Add to Cart View Details

21000 kW 362 PSI Thermodyne Condensing Turbogenerator Set

21000 kW 362 PSI Thermodyne Condensing Turbogenerator Set

Stock #AG61846

Used condensing turbogenerator set made by Thermodyne (France). Steam parameters: inlet pressure 25 bar. Inlet temperature 330 degrees Celsius. Inlet steam consumption 100 000 kg/hour. Turbine has 4540 rpm. Generator made by Jeumont (France) 50 Hz, 3 phase, 5500 volts, 2747 a.

Location: ASIA

Add to Cart View Details


Steam Turbine Generators Condensing - USA

 Used 2500KW 250 PSI  Condensing  Steam Turbine Generator

Used 2500KW 250 PSI Condensing Steam Turbine Generator

Stock #ZG62865

Used Dresser-Rand frame S-6, 2500 kw single valve multi stage condensing steam turbine, 6000 rpm, inlet steam 200 to 300 psig, 500 to 600 deg f, exhaust 2”hga, CW rotation looking from governor end, 1 curtis 6 rateau stages, 6” class 600 inlet size, 30” class 125 up exhaust. Ideal 2941 kva, 2500 kw, 4160 v, 3 phase, 60 hz. Air cooled with brushless exciter. 1800 rpm. Graham surface condenser, 3271 sq. ft, 43,000 lbs/hr steam condensed. Hand valve for part load operation. Lube oil system, gland steam condenser. SCOPE OF SUPPLY: Steam turbine, gear reducer, generator, trip and throttle valve, lube oil system mounted on common skid Condenser, air ejector, condensate extraction pumps with motor Generator terminal box with surge protection system, ct’s, pt’s Local turbine gauge board. Neutral ground resister Manuals and drawings

Location: South USA

Add to Cart View Details

11 mW 50 Hz  Power  Plant ABB Generator Condensing

11 mW 50 Hz Power Plant ABB Generator Condensing

Stock #ZS20933-2

Used power plant with 120 tph of steam at 62 ATI at 430C temperature and 11mw ABB / CKD condensing turbogenerator. New 2015 (4) burners for gas and fuel oil. Used to work with 1500 tpd sugar refinery from raw sugar.

Location: Europe

Add to Cart View Details

6600 kW 600 PSI Dresser-Rand Steam Turbine

6600 kW 600 PSI Dresser-Rand Steam Turbine

Stock #ZG60449

Manufacturer: Dresser-Rand Type RD6M2 Steam Turbine rating: 6600 kW inlet steam: 600 PSIG/750 deg F exhaust steam: 3"HGA steam rate: 10.38 lbs/KWH speed: 5361 rpm turbine rotation: CW (view from governor end) gear reducer: manufacturer: Lufkin rating: 9215 HP speed: 5361/1800 rpm manufacturer: GEC alsthom rating: 7765 kVA voltage: 6900 V/3 phase, 60 Hz, 0.85 pf type: air cooled scope of supply: steam turbine with gear reducer mounted on one skid generator with brushless exciter turbine inlet trip valve air cooled condenser designed for 58,260 lbs/hr turbine control panel generator control panel Woodward 505 governor panel Lube oil system spare parts, manuals and drawings year built 1995 shutdown 2011

Location: USA

Add to Cart View Details

8000 kW Siemens Steam Turbine

8000 kW Siemens Steam Turbine

Stock #ZG59485

Used Siemens steam turbine model EK8002. (2) 4000 kW, 8000 rpm, 42 kg/square centimeter. 10/11 kg/square centimeter 1st extraction; 6/7 kg/square centimeter 2ND extraction. Consisting of: (2) electrical generators with (2) boilers to produce 4MW plus 40 tons/hour of steam @ 100 PSIG each, consisting of the following equipment: - (2) 40 tons/hour steam boilers manufactured by Cerrey (combustion Engineering in Mexico), type 30VPI12M, series 7721 and 7722, 50.3 kg/sq. Cm. - (2) centrifugal blowers, 400 HP and 300,000 cu. M. Of air; (2) Viking 5 HP fuel oil, 1200 rpm pumps; (2) 7 sq. M. Shell and tube type fuel oil heaters; (2) fuel oil gear pumps for ambient temperature, 3 HP, 1750 rpm; (1) carbon steel caustic soda tank; (1) carbon steel sulfuric acid tank. - water treatment system (demineralize) with: (1) 6.5 cu. M. Cation tank (Zeolites; (1) 120 cu. M./hour gas release tower with PVC Rashing ring packing; (1) 2.5 cu. M. Anion tank (Zeolites; 25 HP pump for tower and 3 HP fan for tower. - (4) high pressure water pumps manufactured by Zulzer, (3) small carbon steel flash tanks, and (2) small centrifugal pumps for flash tanks. - (2) Siemens 4000 kW steam turbines type EK8002, 8000 rpm, 42 kg/sq. Cm steam input, 1st extraction: 10/11 kg/sq. Cm., 2ND extraction 6/7 kg/sq. Cm. - all auxiliary equipment such as vacuum pumps, control panels, fan for cooling control pane, and air handling unit for turbine room. - (2) Siemens 60 Hz, 6600 volt electrical generators.

Location: Mexico

Add to Cart View Details

9500 kW 850 PSI Murray (Dresser-Rand) Steam Turbine

9500 kW 850 PSI Murray (Dresser-Rand) Steam Turbine

Stock #ZG60651

Steam turbine: manufacturer: Murray (Dresser-Rand) rating: 9500 kW rating with zero extraction: 6500 kW inlet steam: 850 PSIG/750 deg F extraction steam: 125 PSIG extraction steam flow: 0 to 50,000 lb/hr maximum inlet steam flow: 120,000 lbs/hr maximum exhaust flow: 75,000 lbs/hr number of stages: 9 speed: 4711 rpm inlet steam flange: 6" side exhaust flange: 48" top control: Woodward 505E gear reducer Lufkin 4700 to 1800 rpm generator: manufacturer: ideal rating: 11177 kVA kW: 9500 pf: 0.85 type: Tewac exciter: brushless 25 kW. Year built: 2001 last year run: 2008 scope of supply steam turbine generator skid Lube oil system, condenser, air ejector and turbine control panel. Excluded: cooling tower, gen control panel and breakers

Location: USA

Add to Cart View Details

25000 kW 850 PSI Westinghouse Steam Turbine Generator

25000 kW 850 PSI Westinghouse Steam Turbine Generator

Stock #ZG60184

25 MW Westinghouse Steam turbine generator. Inlet pressure: 59.76 kg / cm2 (850 psi), inlet temperature: 482.2° Celsius. (900° Fahrenheit) rpm 3600, stages 13, model: YD1, 13.800/296V, 250 kVA dry generator, 1972. Generator manufacturer: Westinghouse model 500886 power 25 MW nominal tension 13.800 KV - 60Hz - rpm 3600 manufacture date: 1972. Condenser not included.

Location: SOUTH AMERICA

Add to Cart View Details

80,000 KW 1500 PSI Mitsubishi Steam Turbine Generator

80,000 KW 1500 PSI Mitsubishi Steam Turbine Generator

Stock #ZG62341

Turbine: Manufacturer/Type: Mitsubishi Type Sc1f-29.5”Ax, Single Cylinder, Axial Exhaust Output: 80,000 Kw Inlet Steam: 1500 Psig/970 °F Induction Steam: 90 Psig/400 °F Exhaust Steam: 2” Hga Number of Stages: 12 Speed: 3600 Rpm Generator: Manufacturer/Type: Mitsubishi Type Mb Rating: 94118 Kva, 13800 V, 0.85 Pf, 3 Phase, 60 Hz Speed: 3600 Rpm Rotation: Ccw From Drive End Scope of Supply: Steam Turbine, Generator, Trip And Throttle Valve, Lube Oil System, Condenser, Air Ejector, Condensate Extraction Pumps with Motor Generator Terminal Box With Surge Protection System, Ct’s, Pt’s Manuals And Drawings History Unit Built 2001 Part of Combined Cycle Power Plant.

Location: Midwest USA

Add to Cart View Details