Cogeneration Plants


Cogeneration Plants - Czech & Slovakia

Cogeneration Plants - Europe

(2) 400 kW 380 Volts 50 Hz Biogas Power Plant

(2) 400 kW 380 Volts 50 Hz Biogas Power Plant

Stock #RG8914

Used 0.8 MW MWM CHP power plant including (2) engines rated 400 kW fuelled by biogas and held in soundproof containers. Made in 2011 and still operating 2 days per month. 11000 hours of use recorded by October 2015. Equipment list includes: - (2) MWM TCG 2016 V08 C engines rated 400 kW electrical output, 395 kW thermal output +/- 8%, electrical efficiency 42.8%, thermal efficiency 42.1%. Gas train, gas mixer, generator, voltage stabiliser, power factor controller, coupling, control unit and switchboard. - exhaust silencer. - CHP power cabinet. - heat exchanger cabinet, heat extraction / hydraulic system, plate heat exchanger, surge tank. - electrical circulation pump for combustion engine. - mixture cooling. - exhaust gas heat exchanger - soundproofed container, 65db(a) in 10M, emergency cooler, engine control system Each 400kW engine may be available separately; more information on request.

Location: EUROPE

Add to Cart View Details

Biomass CHP Plant 5000 KW, 6300 V

Biomass CHP Plant 5000 KW, 6300 V

Stock #AS60924

Used wood biomass fired power plant with the electrical output capacity of 5000 KW per hour. The power plant has been designed in 2005 as a combined heat and power plant (CHP) to burn wood biomass residue as a fuel. Currently plant is shut down with about 100K operation hours. The power plant is complete and is still installed on the foundations. Main equipment of the plant: (2) biomass steam boiler sets, each with the steam flow of 12,4 t/h. General steam parameters are as follows - 24,8 t/h, 72 bar, 490*C. Overall heat power is 20,476 kWth (two boilers). Hydraulic moving gate, Dry de-ashing system, Flue gas recirculation system, Multi cyclone system, Electrical precipitation system. Fuel is supplied via the system of mowing flours and conveyors. (1) extraction-condensing steam turbogenerator set with the electrical output of 5 MWel. Turbogenerator parameters - 5000 KW, 12000 RPM, 24,75 tph - 15 tph, 65 bar - 1.7 bar, 480*C - 115*C, 50 Hz, 6.3 kV, 0.584 kA. Separate water cooling system. The plant is fully automated with control system by Siemens. The plant is also is equipped with the the following equipment: Vacuum condenser, Heating condenser, air cooling system, water treatment plant, feed water tank, transformer, chimney, etc. All equipment is reported to be well maintained and in good condition.

Location: Europe

Add to Cart View Details

Used biomass power plant with electrical output 7600KW, 40-60 t/h of the steam, 40-49 bar, 395*C.

Used biomass power plant with electrical output 7600KW, 40-60 t/h of the steam, 40-49 bar, 395*C.

Stock #AG61932

Used biomass power plant with the capacity 7.6 MW. The main equipment of the plant is following: (2) Used water tube boilers with membrane walls, individual steam capacity 20-30 t/h, pressure 40-49 bar, 395*C, fuel type – biogas. (2) New Gasification reactors 20MWt, with two torsional combustion chambers, can operate on the wood chips, sunflower husk and other related fuels with the moisture content between 10% to 50%. (1) Used but condensing Turbo-Generator with 7600 KW electrical output and steam extraction, steam parameters; 39-43 bar, 390-420*C, 15.000 kVA, 11000V. Steam consumption 40 t/h. New control cabinet and new burners 2 pcs, Turbo-Generator revised by OEM. Auxiliary supply includes following; Condenser, steam pipelines, flanges and drainage system, oil and generator cooling system, boiler feed tank, pumps, control cabinets, water treatment system, two chimneys, set of technical files & drawings, supporting structures and leaders. All equipment produced in Europe, more information on request.

Location: Europe

Add to Cart View Details

138.38 MW Combined Cycle Natural Gas Power Plants

138.38 MW Combined Cycle Natural Gas Power Plants

Stock #RG9557

(2) x 138.38 MW Combined Cycle Power Plants fuel type Natural Gas. Rated Output (existing-Gas Motors) : 126.1 MW Rated Output CCPP : 138.38MW Generation Capacity : 1,107,040,000 kWh/Year           Technical Characterisics: Type of Generation : Combined Cycle Fuel Type : Natural Gas Number of Units : 13 Gas Motors/Gen. + 1 ST/Gen Gas Motors Manufacturer : Wartsila Type of Gas Motors : 20W34SG Rated Output (Gas Motors) : 9.73 MWe Efficiency (Gas Motors) : %45 Steam Turbine Manufacturer : SIEMENS Type of Steam Turbine : SST – PAC - 300 Power Output : 12.280 MWe Number of Boiler : 13 Capacity Boilers : 4,6 t/h, 59,8 t/h (total) Steam Pressure : 15 bar Steam Temperature : 350 0C Efficiency of Combined Cycle(Overall) : %48.5 Rated Power of TRs : 100 MVA Further information upon request

Location: EUROPE

Add to Cart View Details

140 kw Gasification and CHP Plant

140 kw Gasification and CHP Plant

Stock #RG9456

Used modular gasification plant made circa 2001 and currently used for R&D purposes. Gasification plant uses 'down draft' process to produce syngas from solid biomass including wood chips and wood pellets. Equipment includes: - Feed mechanism - Gasifier. Top loading down draft type including lock hopper feed mechanism, grate and auto de-ashing. Can use wood pellets and wood chips. - De-ashing system - Gas cooler. Water cooled. - Filtration unit - Ash hopper collection system - Piping - Instrumentation for control panel and PLC All of the above is installed into modular framework. Plant used for R&D purposes.

Location: United Kingdom

Add to Cart View Details

227 kW 50 Hz Biogas CHP Plant Unused

227 kW 50 Hz Biogas CHP Plant Unused

Stock #RG9832

Unused containerised biogas CHP Tedom Cento T series system made in 2015. Output can be modulated between 80 and 227 kW. System includes motor-generator, heat radiator / heat to an external source, exhaust silencer, power switchboard. Could also reportedly use LPG.

Location: United Kingdom

Add to Cart View Details

250kW CHP Cogeneration Biogas Power Plant

250kW CHP Cogeneration Biogas Power Plant

Stock #RG9435

Unused wood gas powered CHP plant designed by Schmitt Enertec. Output capacity is 250 kW electrical power and 378 kW thermal power with outlet temperature of 90 degrees. Unit was built in 2013 and has only run a few hours during the OEM testing procedure. - Also available and included in the sale if wanted: gasifiers and filters designed to produce wood gas. NOTE that the gasifiers do not work.

Location: Europe

Add to Cart View Details

419.9 MW Combined Cycle Power Plant Fuel Type Natural Gas

419.9 MW Combined Cycle Power Plant Fuel Type Natural Gas

Stock #KS61696

Reportedly unused 419.9 MW combined cycle power plant Siemens. Turbine Siemens type SGT3-4000, Steam turbine Siemens type SST5-3000, condenser Scin, automated system for GT and ST: SSPA-T3000. Requires new generator, old generator is damaged. Totally 475 units in cargo. It is power plant based on Combined Cycle Gas Turbine using after burning of gas recovering of heat in Condenser for Steam turbine for more power output. More info upon request.

Location: EUROPE

Add to Cart View Details

800 kW 380 Volts 50 Hz Biogas Power Plant

800 kW 380 Volts 50 Hz Biogas Power Plant

Stock #RG8915

Used 800 kW landfill biogas power plant reportedly made in 2011. Still operating and currently with 11,000 hours of use. Plant includes the following equipment: - gas extraction system with capacity 500 M3/hour. Option to increase capacity to 1000 M3/hour with additional compressor. - system with vertical wells can cover 3.2 ha, system with horizontal wells can cover 7.5 ha of landfill area. - remote monitoring. - high temperature flaring unit. Landfill gas burning temperatures between 1000-1200 degrees Celsius. - (2) 400 kW container based MWM TCG 2016 V08 C engines. Plant information sheet available on request.

Location: EUROPE

Add to Cart View Details

2000 kW 400 Volts Cogeneration Plant

2000 kW 400 Volts Cogeneration Plant

Stock #L0909

Used 2000 kW cogeneration plant, 400 volts, consisting of three Deutz TGB 620 natural gas engines with heat recovery units. Please see attachment for technical details.

Location: EUROPE

Add to Cart View Details

2400 kW 11000 Volts 50 Hz Waukesha Gas Fired CHP Plant

2400 kW 11000 Volts 50 Hz Waukesha Gas Fired CHP Plant

Stock #RG8154

Used Waukesha 2.4MW gas fired CHP plant. Main components of the plant are (1) Waukesha model 12V-AT27GL gas fired engine with a Leroy Somer alternator rated at 2400 kW, 50 HZ, 11,000 volts. Natural gas compressor, starting air compressor with receiver, exhaust system, heat recovery boiler, lube oil system, and fire suppression system. Includes switchgear, computer and national grid synchronisation system. The generator is housed in an acoustic enclosure.

Location: UK

Add to Cart View Details

4200 kW 11000 Volts 50 Hz Siemens Power Plant

4200 kW 11000 Volts 50 Hz Siemens Power Plant

Stock #RG7655

4.2MW Typhoon frame mounted power plant. Natural gas & diesel fuel configuration. Main gearbox and alternator included rpm 1500. Please see attached document for full technical details.

Location: TURKEY

Add to Cart View Details

4500 kW 10000 Volts 50 Hz Turbo Mach Spa. Turbo Gas Cogen Plant

4500 kW 10000 Volts 50 Hz Turbo Mach Spa. Turbo Gas Cogen Plant

Stock #RG7305

Used 4500 kW 5750 kVA 50Hz turbo gas cogen plant. Manufacturer Tuma - Turbo Mach spa. Year of manufacture 1995. New turbine and generator in 2001. Fuel: natural gas (CH4) gas comsumption: 1.200.000 M3/month; 65/70% for power, 30/35% for steam gearbox reductor cat-solar Leroy Somer power generator for 4.6 MW / 5750 kVA at 10.000 V, 1500 rpm solar centaur 50-T6200 gas turbine bono heat recovery boiler, with 10 ton/hr steam production at 10 bar water demineralization system with condensate recovery and make-up water tank degaser, 2 high pressure pumps for boiler feeding automatic turbine washer

Location: EUROPE

Add to Cart View Details

4900 kW 600 Volts 50 Hz Siemens Power Plant

4900 kW 600 Volts 50 Hz Siemens Power Plant

Stock #RG8415

Used 4.9 MW, 6000/15000V, 50 Hz power plant. Reported to be in good condition and to have been regularly overhauled according to Siemens regulations. Plant consists of the following main elements: - Siemens SGT 100 dry low Nox gas turbine made in 1997. Power 4.9 MW, frequency 50 HZ, efficiency 31%, heat consumption 11.613KJ/KWH, power turbine speed 17,384 min-1, compressor pressure ratio 15.6:1, mass flow 20.6kg/S, exhaust temperature 531 degrees Celsius, hours since last overhaul 4000. - Babcock heat recovery steam generators made in 1997. Steam 30 tons/hr, pressure 20 bar. - Bolletino transformer made in 1997. Output voltage 6000 / 15000 volts, phases 3, power 6090 kVA, power factor 0.8, speed 1500 rpm, protection IP 3.

Location: EUROPE

Add to Cart View Details

6600 kW 6000 Volts 50 Hz Cogeneration Plant

6600 kW 6000 Volts 50 Hz Cogeneration Plant

Stock #RG9671

6.6 MW 6000 Volts 50 Hz cogeneration plant reportedly made circa 2000 and shut down in 2010 due to rising gas prices. Approximately 34,300 hours of use. Main equipment includes: - Umisa firetube steam boiler, flow rate 20 tons/hour, pressure 7-8 bar, temperature 170 degrees Celsius, 15.2 MW burner power, volume 55.1 m3, fueled by natural gas. - (2) Ulstein Bergen KVGS-18G3 engines, 18 cylinders with diameter 250mm, 300mm stroke, 14.7dm3 stroke volume/cyclinder, 1000 rpm, 4 stroke, turbocharged, cooling air intake, designed for natural gas. Otto cycle. - (2) Leroy Somer power generators, 6000 V, 3-phase, 50 Hz, power factor 0.8. - ABB Transformer, ratio 22/6.3kV, 8000 kVA. - ABB low voltage transformer, ratio 6/0.4 kV, 630 kVA. - Water treatment equipment, osmosis process. - Cooling tower, 4kW fan power, hot water flow 344m3/hour. - Ventilation system. - Compressed air system including (2) Sperre compressors with working pressure 31 bar, 9.5 kW motor, 1.73m3/min. - (2) Termojet air storage tanks, capacity 1m3 each.

Location: Europe

Add to Cart View Details

7832 kW 11000 Volts 50 Hz Deutz Cogeneration Plant

7832 kW 11000 Volts 50 Hz Deutz Cogeneration Plant

Stock #RG8999

Used 7832 kW, 11000 V, 50Hz cogeneration plant that started operating in 2005 and was shut down in 2019. Includes (2) Deutz (MWM) TBG 632 V 16 engines fuelled by natural gas. Engines have approximately 45,000 to 50,000 hours of use. - Each TBG 632 engine has the following specifications: 3,916 KWE, 16 cylinders, speed 1000 rpm, electrical efficiency 41.9%, thermal efficiency 44%, exhaust gas flow 20897 kg/H, gas temperature 466 degrees Celsius. - Steam generation specifications per engine: max steam flow with exhaust gases from engine 3 TPH, normal operating pressure 7.5 bar. Equipment list includes: - engines, generators, plate heat exchangers, oil tanks (fresh and waste), oil heat exchangers, platforms, ventilation canals, boilers, deaeroator, economisers, bypass valves (dampers), stacks, feeding pumps, platforms, pumps, heat exchangers, control panels and transformers. Each Deutz system is available separately. More details available on request.

Location: Europe

Add to Cart View Details

8730 kW 11000 Volts 50 Hz Wartsila Gas Units

8730 kW 11000 Volts 50 Hz Wartsila Gas Units

Stock #RG8191

Used 8730 kW Wartsila 20V34SG (spark gas) units. Power 8,730 KWH. Fuel 100% natural gas. First used in 2005, run for 48,000 hours. Consists of: - Generators. Capacity 10,913 kVA, frequency 50 Hz, cos 0.8, volt 11,000 V output; - Neutral cubicle; - Step-up tranformer. 11kV/33kV 11 MVA Onan/ONAF 33 kV, 5 steps output; - Start air compressor; - Boiler. Pressure 13 Barg saturated stream, steam capacity 4.7 ton/HRS production; - Cooling tower.

Location: EUROPE

Add to Cart View Details

9680 kW 6000 Volts 50 Hz Cogeneration Plant

9680 kW 6000 Volts 50 Hz Cogeneration Plant

Stock #RG9191

Used 9.68 MW cogeneration plant fed by heavy fuel oil (HFO). Year of manufacture 1999, start up in 2000, shutdown in 2014. Currently in maintained condition. Plant includes the following equipment: - engine made by Bazan-man, type 40/45 16V, 9680 kW, 600 rpm, 45405 hours of use. - oil mist detector made by Visatron, model VN 215/87. - lubrication pumps. Driven by 1.5kW, 380V, variable speed motor. - (2) fuel purifiers made by Alfa Laval, model MFPX 307. Driven by 7.5kW, 380V, 50HZ, 2855 rpm motor. - oil purifier made by Alfa Laval, model LPOX 709. Driven by 12kW, 380V, 1460 rpm motor. - fuel supply module with (4) pumps of 3.8 M3/hour. Motor 7.5kW, 380V. Automatic fuel heater, self cleaning filter 35 microns. - service tanks room: (1) 500 litre tank for injectors made of stainless steel. (1) 1500 litre tank for cylinders. (1) 1000 litre oil tank. (1) 10,000 litre fuel tank. (1) 5000 litre diesel tank. - PLC made by OMROM, 32 bits. - Visco chief VCUI-160 viscometer made by Alfa Laval. - Triphasic brushless alternator. 11616 kVA, 1132 a, 6000V, 50 HZ, 600 rpm, performance 96%. - boiler made by Lopez HNOS S.a., model CRP 790, max steam production 4500 kg/hour, thermal power 3,000,000 KCAL/hour. - wet filters for 245 litres of oil. - Extraor fans. (6) at 5.5 kW, 380V. - control panel. - transformer, 12.5 MVA continuous power. - spare parts.

Location: Europe

Add to Cart View Details

10,200 kw 50Hz Co-Generation Plant

10,200 kw 50Hz Co-Generation Plant

Stock #RG9578

Used 10.2 MW 50 Hz cogeneration plant consisting of (3) generators rated 3.4 MW each. Engines were commmissioned in 2007 after being rebuilt and converted to use heavy fuel oil feedstock. Plant was shut down in 2008.

Location: Europe

Add to Cart View Details

34920 kW 11000 Volts 50 Hz Wartsila Power Plant

34920 kW 11000 Volts 50 Hz Wartsila Power Plant

Stock #RG8220

Used 34920 kW Wartsila power plant comprising of the following: (4)used 8730 kW Wartsila 20V34SG (spark gas) units. Power 8,730 KWH X 4 (units) = 34,920 KWH. Fuel 100% natural gas. First used in 2005, run for 48,000 hours. Consists of: (4) generators. Capacity 10,913 kVA, frequency 50 Hz, cos 0.8, volt 11,000 V output; (4) neutral cubicles; (4) step-up tranformers. 11kV/33kV 11 MVA Onan/ONAF 33 kV, 5 steps output; start air compressors; (4) boilers. Pressure 13 Barg saturated stream, steam capacity 4.7 ton/HRS production; (4) cooling towers.

Location: EUROPE

Add to Cart View Details

36500 kW Cogeneration Plant

36500 kW Cogeneration Plant

Stock #V813-200

Used 36.5 MW power cogeneration plant (60HZ) is equipped with three boilers. Boiler #1 & #2 are Riley Stoker coal-fired boilers, boiler 1 is 125 klb per hour at 900 psi and boiler 2 is 125 klb per hour at 900 psi. Boiler 3 is a Detroit Stoker coal-fired boiler, rated at 290 klb per hour at 425 psi. The boilers provide steam to run one 15 MW GE steam turbine & generator and one 20 MW Mitsubishi steam turbine & generator. Power plant inventory spares are also available. Part of cane sugar plant.

Location: HAWAII

Add to Cart View Details

53000 kW 11000 Volts 50 Hz Combined Cycle Cogeneration Power Plant

53000 kW 11000 Volts 50 Hz Combined Cycle Cogeneration Power Plant

Stock #RG7793

Used 53MW combined cycle cogeneration power plant consisting of the following: (1) off used GE (Nuovo Pignone) model FRMS 6001 (B) 6541 gas turbine. Power rating ISO 39MW with efficiency rating 31.9%. Natural gas / distillate oil fuel configuration but only used on natural gas since new. Unit includes steam injection. Unit includes electric motor + torque converter for start-up. Unit is mounted in acoustic booth and skid mounted. (1) off used Flender-Graffenstaden main gearbox type TRL 65 CV. Unit rated 5113.6 rpm input with 3,000 rpm output. (1) off used GEC Alsthom turbine generator. Power output rated 46,000 kVA, 3,000 rpm, 50 hertz. Power factor 0.85, 39,100 kW, 2414 amps, 11,000 volt, insulation class F. Cooling system CACW. (1) off used auxiliary boiler rated 60 ton/hour with economiser and auxiliary combustion system. (1) off used Ansaldo steam turbine model CDI 635 R, power rating 18,700kW. HP inlet pressure at 68.5 bar at 498 deg.C with flow of 64.5 T/R in winter, 11a=MP-11A extraction pressure rated 14.5 bar at 315 deg.C. LP inlet pressure operated between 6 bar to 6.4 bar at 280 deg.C. With flow of 13.5 T/H. (1) off used Ansaldo steam turbine generator, power output 23,000kVA, 11,000 volt. Cooling system CACW. (1) off used reverse osmosis water treatment plant with double resin DEMI line with final mixed bed. (2) off used reciprocating gas compressors rated 11-19.5 bar pressure. (2) off used Ingersoll Rand model SSR M55/75 air compressors. (1) off used ingersollrand model SSR M22 air compressor. (4) off used transformers. Electrical equipment includes: GEC Alstrom AKG 400 L18 motor control centre, ABB generator control panel and ABB synchronising. Balance of plant includes: turbine control system Mark V, air intake/filtration system, exhaust silencer, oil cooler, fire & gas system with detectors. Plant commissioned in 1994 and last ran in 2010.

Location: EUROPE

Add to Cart View Details

55,000 kW 10500 Volts 50 Hz Coal Fired Power Plant

55,000 kW 10500 Volts 50 Hz Coal Fired Power Plant

Stock #RG9801

Used 55 MW coal fired power plant made in 1969 and shut down in 2013. Major components include: - Twin drought boiler with natrual circulation commissioned in 1969 but revamped in 1995. Steam paramaters 190 tons/hour, 90 bar, 525 degrees Celsius. Fueled by hard coal / HFO. - Horizontal split, single casing condensing steam turbine rated 55 MW with 10 MWth heat extraction. - 2 pole generater with air cooling and static excitation. Rated 62.5 MVA, 10500 Volts, 50 Hz, 3000 rpm. - Step-up transformer 10.5/110 kV.

Location: Europe

Add to Cart View Details

58000 kW 11000 Volts 50 Hz Combined Cycle Cogeneration Power Plant

58000 kW 11000 Volts 50 Hz Combined Cycle Cogeneration Power Plant

Stock #RG8861

Used 58 MW combined cycle cogeneration power plant reportedly commissioned in 2002 and shut down in 2013. The equipment is available for sale separately or as a whole power plant. The following equipment is included / available: - (1) gas turbine 1 made by Nuovo Pignone under licence from GE in 2002, model PGT10B-1: 62,068 hours use, 191 hot starts, 1,051 cold starts, last major overhaul August 2012 by GE. Since last overhaul 8,515 hours use, 18 hot starts and 43 cold starts. Type multi-shaft heavy duty gas turbines. ISO rating 11,000 KWE, ISO heat rate 11,414 KJ/KWH, speed 11,000 rpm, thermal efficiency 32.5%, exhaust temperature 487 degrees Celsius, burner DTY Lox NOx emissions, control system Suvimac II+. - (1) gas turbine 2 made by Nuovo Pignone under licence from GE in 2002, model PGT10B-1: 64,861 hours use, 166 hot starts, 1,063 cold starts, last major overhaul August 2011 by Europower. Since last overhaul 12,259 hours use, 30 hot starts, 185 cold starts. Type multi-shaft heavy duty gas turbines. ISO rating 11,000 KWE, ISO heat rate 11,414 KJ/KWH, speed 11,000 rpm, thermal efficiency 32.5%, exhaust temperature 487 degrees Celsius, burner DTY Lox NOx emissions, control system Suvimac II+. - (1) generator made by Ansaldo with apparent power 13,569 kVA, active power 11,000 kW, power factor 0.8, rated speed 1,500 rpm, voltage 11,000V, current 712a, phases 3, frequency 50HZ . - (2) HRSG made by Macchi. Thermal rating 55330 kW, steam flow 65700 KH/hour, steam pressure 130 bar, fuel Wasate heat / Siderurgic gas / natural gas. - (1) steam turbine made by Nuovo Pignone model HNK50,3.2. Configuration 1 impulse stage and 62 reaction stages, rated power 44500 kW, rated inlet flow 131400 kg/hour, rated inlet pressure 110 bar, rated inlet temperature 510 degrees Celsius, rated speed 3000 rpm. - (1) generator made by Jeumont Industrie. Rated apparent power 51500 kVA, power factor 0.8, active power 41200 kW, rated voltage 11000 V +/-5%, current 2703a, 3 phase, rated speed 3000 rpm, 50HZ . - (1) condenser made by Caldemon. Surface condenser with 2 passes and cooling medium sea water. - includes transformers and approximately 4km of 132KV transmission lines.

Location: Europe

Add to Cart View Details

65000 kW 50 Hz GE Power Plant

65000 kW 50 Hz GE Power Plant

Stock #RG9337

Used 65 MW dual fuel GE Power Plant made during 2001/2002 and now decommissioned. Total hours of use 77,000. Last major overhaul was in 2008 for the GTG and in 2013 for the STG; plant has since had 28,100 hours of use. Plant includes the following major equipment: - GE Frame 6B 42 MW Gas Turbine Generator made in 2001. - Siemens 22 MW Steam Turbine Generator made in 2002. - Standard Fasel Heat Recovery Steam Generator (HRSG) with capacity 65 tons/hour of steam made in 2001. Gas turbines also available separately.

Location: Europe

Add to Cart View Details

115000 kW 50Hz GE Power Plant

115000 kW 50Hz GE Power Plant

Stock #RG9341

Used 115 MW dual fuel GE Power Plant made during 1997/1999 and now decommissioned. Hours of use are GTG1 111535, GTG2 100533. Last major overhaul was 2007 (STG), 2004 (GTG1) and 2006 (GTG2). GTG1 and GTG2 have since had 42118 and 56004 hours of use respectively. Plant includes the following major equipment: - (2) GE Frame 6B 40 MW Gas Turbine Generator Sets made in 1997. - Siemens 40 MW Steam Turbine Generator made in 1999. - Desa-BWG Heat Recovery Steam Generator (HRSG) with capacity 61.2 tons/hour of steam made during 1997/1998. Gas turbines also available separately.

Location: Europe

Add to Cart View Details

120000 kW Ansaldo Energia Gas Turbine Generator Set

120000 kW Ansaldo Energia Gas Turbine Generator Set

Stock #RG8873

Used incomplete 120 MW gas turbine generator set reportedly made by Ansaldo Energia under licence from Siemens. Commissioned in 1999 and decommissioned 31st December 2013. Service hours 108242, hot starts 716 (including failed starts), cold starts 510 (121 @ high rate ramp). Last major overhaul was hot gas path inspection in October 2012 by Ansaldo Energia. Service hours since overhaul 8684, hot starts since overhaul 63 (including failed starts), cold starts since overhaul 60 (26 @ high rate ramp). The remaining items from this plant are:- - gas turbine-generator set made by Ansaldo Energia (Italy) under licence from Siemens, fueled by blast furnace gas, coke oven gas and natural gas mix. Active power of 112800 kW, power factor 0.8, speed 3000 rpm, voltage 15000V, current 5427 a, 50 HZ - fuel gas compressor - heat recovery steam generator - 100/152 MVA transformer - 20/25 MVA transformer more details available on request.

Location: Europe

Add to Cart View Details

130000 kW 50 Hz GE Power Plant

130000 kW 50 Hz GE Power Plant

Stock #RG9336

Used 130 MW dual fuel GE Power Plant made during 2001/2002 and now decommissioned. Hours of use are GTG1 80100, GTG2 79400. Last major overhaul was in 2009 and GTG1 and GTG2 have since had 35,700 and 36,600 hours of use respectively. Plant includes the following major equipment: - (2) GE Frame 6B 40 MW Gas Turbine Generator Sets made in 2001. - Siemens 50 MW Steam Turbine Generator made in 2002. - Standard Fasel Heat Recovery Steam Generator (HRSG) with capacity 65 tons/hour of steam made in 2002. Gas turbines also available separately.

Location: Europe

Add to Cart View Details


Cogeneration Plants - USA

Used 5000 KW Biomass Power Plant

Used 5000 KW Biomass Power Plant

Stock #ZG62575-2

Used wood biomass power plant with the electrical output 5000 KW/h. Main equipment of the plant - Boiler Weiss with 25.5 TPH / 74 bar / 500*C steam output, and steam turbine MAN with 5 MW / 63 bar / 477*C. Fuel, wood chips with the moisture content up to 50%. More information on request.

Location: Europe

Add to Cart View Details

Solar T70 Gas Turbine with Rentech HRSG

Solar T70 Gas Turbine with Rentech HRSG

Stock #ZG63017

Solar Taurus 70, Solo Nox Gas Turbine Gen Set w/HRSG, Built 2016. Generator Construction/Cooling Open Drip Proof (ODP) Applicable Electrical Code NEC/CEC Hazardous Area Classification Class I, Div II, Groups B, C, and D Temperature Rating Point 40° C (104° F) Voltage (V) 4160 Frequency (Hz) 60 Hz Apparent Power (kVA) 8125 Real Power (kW) 6500 Cos Ø (power factor) 0.8 Insulation Class Class F with VPI Temperature Rise Class B 80° C (144° F) Duty Cycle Continuous ODP Generator IP Rating IP 34 Rotor Salient, 4-Pole Stator Windings Form Wound, 3-Phase Exciter Brushless Pilot with PMA Power Leads 6 / WYE Connection Space Heaters - Stator 120V / 60Hz /1 Phase Bearing Type Sleeve Bearing Lubrication / Viscosity See Lubrication System Section Bearing Lube Temperature 60° C Design (90° C Alarm) HRSG built by Rentech; rated 31,509 lbs/hr at 150psi Kentube/Fintube Economizer

Location: Midwest USA

Add to Cart View Details

2.7 MW Biomass (Vegetable Oil) Power Plant

2.7 MW Biomass (Vegetable Oil) Power Plant

Stock #ZG62576

Used 2.7 MW Biomass (vegetable oil) power plant. Built 2007. 8000 operating hours. Engine: No. of cylinders 9 Line Layout Bore 270 mm Stroke mm 380 Unit displacement lt21.8 Total displacement lt196.2 Continuous mechanical power kW 2,763 Effective mean pressure bar 23,5 Rotation speed (r/min) 750 Fuel usable vegetable oil P.C.I. (Lower Heating Value) (MJ/kg) 37 Fuel consumption ( 5%) (g/kWhe) 228 Supply pressure bar 8 Consumption of lubricating oil (g/kWhe) 0,8 Synchronous three-phase alternator with the following characteristics: Reference standards CEI-IEC 34 Rated continuous power kVA 3,283 Correspondents equal to 2,627 kW Yield % 96 Nominal voltage V 400 Frequency Hz 50 Revolutions (rpm) 750 Poles 8 Protection IP 23 Insulation class F Overtemperature class F Maximum ambient temperature (*C) +40 The alternator allows a 10% overload for the time of 1 hour in 12 hours. The alternator will be equipped with an anti-condensation system and a regulator that can vary from 0.8 to 1.

Location: N/A

Add to Cart View Details

750 kW 480 Volts 60 Hz Caterpillar Standby Diesel Generator Set

750 kW 480 Volts 60 Hz Caterpillar Standby Diesel Generator Set

Stock #ZG62295

Used 2011 Caterpillar 750 kW Standby Diesel Generator Set, SN-DWB02800. CAT C27 engine rated 1141 HP at 1800 RPM, SN-MJE02797, EPA Tier 2 certified. 3/60/277/480V, 12 lead re-connectable to other voltages. 1600 Amp main line circuit breaker. EMCP 3.3 digital control panel. UL 2200 listed package. Coolant heater. Sens battery charger. Weather enclosure. 1500 gallon UL 142 listed sub-base fuel tank. 258 hours. Year 2011. CAT factory worldwide extended warranty available for up to 5 years at additional cost

Location: Midwest USA

Add to Cart View Details

4000 KW Biomass Power Plant

4000 KW Biomass Power Plant

Stock #ZG62575

Used 4.4 MW Biomass power plant. Built 2005. The plant is a high-pressure steam boiler plant with multi-cyclone and flue gas dedusting system. Comprised of two identical high-pressure steam boilers with superheaters and feed water preheater. These feed steam into a single turbine. The 2 boilers have a nominal steam output of 14.5 tons/hour. The steam turbine has a maximum generator terminals power of 5MW, at nominal load. Additional specifications available. Fuel: Unchipped bark Wood shavings and sawdust (max share 40%) Wood chips G30 –G100 Fuel specification: Bulk density: S160 –S250 Moisture level: 35 –60 Mass % (max 65%) Lower heating value: Min 1.60 kWh/kg – Max 3.1kWh/kg Ash content: 1% -5%

Location: N/A

Add to Cart View Details

4600 kw Solar Centaur 50 Gas Turbine Generator

4600 kw Solar Centaur 50 Gas Turbine Generator

Stock #ZW62728

SOLAR CENTAUR 50, 4.6MW gas turbine generator w/ SoLoNOx combustion system; CLEAVER BROOKS 90,000 LB/HR heat recovery steam generator; EMERSON VILTER fuel gas booster compressor; E-TECH 6,000,000 BTU/HR vertical flow condensing economizer; Pad Mounted 5MVA, 27.6KV-13.8KV step up transformer; Chilled water system, PLC control systems, MCC.

Location: CANADA

Add to Cart View Details

5000 kW 20 KV 50 Hz Boimass Power Plant

5000 kW 20 KV 50 Hz Boimass Power Plant

Stock #ZW62272

5 MW BIOMASS FUELED POWER PLANT Major Equipment • Production Facilities • Steam boiler 1: 10 MW heat output (12 t / h, 420 ° C, 30/38 bar). An Electrostatic precipitator is connected downstream. • Steam boiler 2: 10 MW heat output (12 t / h, 420 ° C, 30/38 bar). A fabric filter is connected downstream. • Steam boiler 3: oil boiler (6.51 MW, burner controlled to approx. 3 MW) • Turbo-generators Two extraction-condensing turbo-generators # 1: KKK (1.6 MW); Year 1994 # 2: AEG (3.66 MW); 1981; 2008 Total overhauls (All rotating parts revised); Control modernized (automatic start-up and shutdown); Rotary rotation device installed; Oil cooler system modernized. • Flue outlet Suction units per wooden boiler on a chimney 80 m • Water The entire water requirement is covered by a deep well. The facilities consist of; two-stream gravel filter system (drinking water treatment), high tank (220 m³), two-stage softening unit (2 x 18 m³ / h) demineralisation plant. (2 x 1 m³ / h reverse osmosis). • Electrical Voltage level 20 kV; Two feeds to the directly adjacent substation, Turbo-generator Transformers: 1 x 4000 kVA 5,25 / 20 kV 2 x 1600 kVA 0,4 / 20 kV Auxiliary transformer: 630 kVA Emergency Power Generation: 250 kW The operating systems have been retrofitted between 2004 and 2008 to 24 hrs of free operation based on Siemens S7. • Coolers Three fan cooling units (2 x 6.3 MW, 1 x 10 MW) BAC • Sewage Sewage effluents are introduced into a receiving water, • Additional equipment Compressor system for operating air supply Thermal water treatment plant (50 m³ degasser) Heating condenser plant 7 MW • Fuel system Storage space 2000 t storage permit; sliding floor; conveyor belts; magnetic separator; belt scales; 5 h storage tanks with a lower outlet in front of the boilers • Ash disposal Storage space 200 t

Location: EUROPE

Add to Cart View Details

5493 kW 6300 Volts 50 Hz Solar Cogeneration Plant

5493 kW 6300 Volts 50 Hz Solar Cogeneration Plant

Stock #ZG59952

Solar TBM-T60S rated at 5493 kW, natural gas fired, with Leroy Somer 6250 kVA brushless generator, 6300 volts, 50 Hz. Turbine package has 14,291 total hours, and 388 starts. Bono recovery boiler for 12 tons/H of steam at 15 bar. The plant was built in summer 2002 and shut down in 2010.

Location: EUROPE

Add to Cart View Details

7200 KW Solar T70 Cogen Plant

7200 KW Solar T70 Cogen Plant

Stock #ZG62872

Used 7MW Natural Gas Fired Co-Generator Plant: 2015 Solar Taurus 70 Gas Turbine; Rated at 7200 KW, 13,313 Hrs., with 290 Starts, Hyundai Electric Generator 12,470 V, 60 Hz. Cleaver Brooks HRSG with Natcom Lo-Nox Gas Burner with Ammonium Injection System. Boiler Capacity: 165K Lbs/HR @650F; Operating Pressure 150 PSIG. Drawings and Service Records Available.

Location: West Coast USA

Add to Cart View Details

10600 kW 12470 Volts 60 Hz Solar Mars Combined Cycle Power Plant

10600 kW 12470 Volts 60 Hz Solar Mars Combined Cycle Power Plant

Stock #ZG61353

Used 10.6 MW combined cycle power plant consisting of a Solar Mars 100-S gas turbine generator, with HRAG, and steam turbine generator. Gas turbine: manufacturer: Solar type: 100S rating: 10690 kW (ISO) version: 15000S heat rate: 10,515 BTU/KWH (ISO) fuel: natural gas generator: 13125 kVA, 12470 V, 60 HZ, 0.8 pf HRSG: 40,000 lbs/hr 150 PSIG Steam turbine: Murray History: built 1995, shutdown 2008, lift time 90,000 hours, since last overhaul 34,000 hours This combined cycle power plant with 138 KV substation.

Location: USA

Add to Cart View Details

25000 kW 11000 Volts 50 Hz Siemens CHP Plant

25000 kW 11000 Volts 50 Hz Siemens CHP Plant

Stock #ZG61803

Used 2001 Siemens GT10-B2 natural gas fired turbine generator CHP plant, DLE pg, rated at 25 MW with ABB generator rated at 26,250 kVA, 11KV +/- 5%. Operating hours: 47,656 hours equivalent hours: 43,911 hours total starts: 224 total production: 967,906 MWH

Location: EUROPE

Add to Cart View Details

26000 kW 13800 Volts 60 Hz GE Dual Fuel Turbine Generator

26000 kW 13800 Volts 60 Hz GE Dual Fuel Turbine Generator

Stock #ZG62021

Rebuilt 26 MW GE LM2500 dual fuel turbine generator Current configuration: Turbine: manufacturer: GE turbine engine: 7LM2500-PH-LMB-G03 (STIG-50) power output: 26,249 kW, at generator terminal fuel: liquid/gas hours of operation: 7,141 starts: 816 zero houred and ready to ship Generator: manufacturer: Brush Electric Machines Ltd. BADX 7-167ER type 13.8KV, 60 HZ, 3 phase, 3600 rpm, air coupling: power turbine to generator L. O. System: GT L.O. Tank 600L, w/GT driven lube pump,generator L.O. Tank 800L, w/ gen shaft drain pump. Fuel system: fuel pump, filter, fuel control valve,fuel so valve, flow meter. Steam/water injection: steam/water injection control valve,flow meter. Water wash: cleaning tank, nozzle spray manifold. hyd. Start: hydraulic Lube tank 150L. Change pump, circulation pump, filter, hydraulic oil cooler, electric motor.

Location: South USA

Add to Cart View Details

32350 kW 13800 Volts 60 Hz General Electric Cogeneration Plant

32350 kW 13800 Volts 60 Hz General Electric Cogeneration Plant

Stock #ZG61416

Gas Turbine: Manufacturer: General Electric Base load rating: 32350 kW Model: MS6001B , DLN-1 Fuel: natural gas Generator: Manufacturer:General Electric Rating: 40500 'id/a Voltage: 13,800 V, 3 phase, 60 HZ pf:0.8 Armature amps: 1694 Field amps: 685 Field volts: 125 Speed: 3600 rpm History Year built: 1995 Life time starts: 378 Life time hours: 83082 Last overhaul: 2009 Hours since last overhaul: 17,000 Year shutdown: 6/1/2011 Starting: motor 600 HP Following items are not included: MCC generator breaker and generator protection relays

Location: South USA

Add to Cart View Details

32500 kW 6900 Volts 60 Hz Power Plant

32500 kW 6900 Volts 60 Hz Power Plant

Stock #ZS60717

1 Boiler capacity of 80 tons of steam per hour, with pressure 42 kg/cm2, with its peripherals (air preheater, economizer, washer gases) with MCC and control panel 1 boiler capacity of 70 tons of steam per hour at a pressure of 42 kg cm2 +, with its peripherals (air preheater, economizer, washer gas) with MCC and control panel. 3 turbo-electric power generators with a capacity of 7,500 kW each, generating a voltage of 6.9 KV, Westinghouse brand, with capacitors, transformers and control system detached, MCC (motor control center) and control panel. 1 turbo generator Texas / GE - 10,000 kW, generating a voltage of 6.9 KV with condenser, engine control system and control panel generation 3 cooling tower water, brand Alpina, with capacity of 2,000 cubic meters per hour each, with CCM and 5 booster pumps brand IMBIL, also with CCM. 2 cooling towers Anhanguera brand, with a capacity of 1,500 cubic meters each time, with CCM and ARDL 2 pumps of 4,000 M3 / H each. 2 voltage transformers brand WEG, with a capacity of 20/25 MVA, with transforms tion of 6.9 / 138 KV 1 voltage transformer brand WEG, with a capacity of 2.5 MVA, with conversion of 13.8 / 6.9 KV1 voltage transformer brand WEG, with a capacity of 500 kVA, with transformation 13.800V/380V 1 lift 380-13800 10 KV transformer - 2,500 kVA 1 system generation control and timing with delivery network. 1 water treatment plant with capacity of 50 M3/hr, brand Metágua. 1 system decanting water scrubber with CCM. Diesel generator set 1 - engine alternator and Cummins - 1500/1250 kVA - 380 V network 1 power transmission at high voltage (138 KV) 2,100 meters long.

Location: N/A

Add to Cart View Details

58500 kW 13800 Volts 60 Hz Combined Cycle Power Plant

58500 kW 13800 Volts 60 Hz Combined Cycle Power Plant

Stock #ZG60177

FR-6B combined cycle power plant with 1 X FR6B gas turbine 1 X HRSG and 1 X steam turbine generator set. Plant performance: ambient temperature: 48 deg F fuel: natural gas gross output: 58,500 kW plant heat rate: 8,900 BTU/KWH Gas turbine generator set: Gas turbine: manufacturer of turbine: General Electric model number: PG6541B type: Continuous packaged by: GE packager model number: 6A1PB148-1 rating (base/peak) 42400 kW inlet temperature: 48 degrees F speed: 5,100 rpm Gear reducer: manufacturer: Westech rating: 68000 HP speed: 5100/3600 rpm generator: manufacturer: General Electric type: Tewac rating: 46,500 kVA voltage: 13800 V, 3phase, 60 HZ speed: 3600 rpm PF: 0.9 Armature amps: 1845 amps insulation class: F/F (Stator/rotor) control: Mark IV Speedtronic black start: diesel engine fuel: natural gas NOx control: steam injected year built 1992 shutdown: Still connected total life time hours 46,200 hours since last major overhaul 2007 : 1000 hours HRSG: manufacturer: Zurn type: duel pressure steam flow: HP super heated steam: 900 PSIG/900 deg F, 147,726 lbs/hr LP saturated steam: 185 PSIG/384 EF F, 24,623 lbs/hr Steam turbine generator: manufacturer: GE rating: 16,500 kW pressure temperature flow inlet steam: 900 PSIG 900 deg F 132,000 lbs/hr controlled steam: 180 PSIG 0 to 80,000 lbs/hr exhaust steam: 2" HGA 137,400 lbs/hr rating with zero extraction: 16,500 kW steam rate: 8.00 lbs/KWH speed: 5362 rpm inlet steam size: 10" AE steam size: 8" uncontrolled steam size: 6" exhaust steam: 75" governor: Woodward 505E generator: manufacturer: GE rating: 18,333 kVA voltage: 13800 V, 3 phase, 60 HZ pf: 0.9 speed: 1800 rpm Armature amps: 767 amps exciter: brushless, PMG type: Tewac condenser square ft: 16,619 sq ft condenser water flow: 15,947 GPM cooling water inlet temp.: 75 deg F cooling water outlet temp: 92 deg F History of steam turbine generator: Steam turbine generator was installed in 1990. Approximately 50,000 hours Water treatment system: Power house building with 15 ton and 20 ton cranes 115 KV substation, 13.8 KV switchgear, 4160 V motor starters, 480 V MCC, battery and battery charger, ups. Plant history: start up 1992 and operated until 1998, after this date the plant ran as peak standby only

Location: USA

Add to Cart View Details

63520 kW 13800 Volts 60 Hz Combined Cycle Power Plant

63520 kW 13800 Volts 60 Hz Combined Cycle Power Plant

Stock #ZG60442

Used FR-6B combined cycle power plant with 1 X fr6B gas turbine 1 X HRSG and 1 X steam turbine generator set. Plant performance: ambient temperature: 48°F fuel: natural gas/diesel gross output: 63,520 kW plant heat rate: 8,900 BTU/KWH plant net output: 61,275 kW @ 7,763 BTU/KWH gas turbine generator set: gas turbine: manufacturer of turbine: General Electric model number: pg6541B type: continuous packaged by: GE rating (base/peak) 40,910 kW inlet temperature: 48°F speed: 5,100 rpm fuel: natural gas/liquid inlet air: inlet air cooled NOx reduction: water injected gear reducer: manufacturer: Westech rating: 68000 HP speed: 5100/3600 rpm generator: manufacturer: general electric type: Tewac rating: 47,700 kVA voltage: 13800 V, 3phase, 60 HZ speed: 3600 rpm pf: 0.9 Armature amps: 1845 amps insulation class: F/F (Stator/rotor) control: Mark iv Speedtronic black start: diesel engine fuel: natural gas/diesel NOx control: water injected HRSG: manufacturer: Nooter/Eriksen rating: 172,600 lbs/hr HP steam: 1300 PSIG/950°F IP steam: 190 PSIG/450°F emission control: ammonia injection year built 1990 shutdown: still connected total life time hours 84,936 hours total life time starts: 1,182 hours since last major overhaul 1999 : 27104 hours starts since last major overhaul 1999: 714 hours since last hot gas path inspection 3,226 steam turbine generator: manufacturer: ABB VAX axial exhaust rating: 22610 kW pressure temperature flow inlet steam: 1300 PSIG 950 deg F 172,600 lbs/hr exhaust steam: 0.74 PSIA process steam: 22,515 lbs/hr @ 180 PSIG generator: manufacturer: ABB rating: 27,300 kVA voltage: 13800 V, 3 phase, 60 HZ pf: 0.9 speed: 1800 rpm Armature amps: 1144 amps exciter: brushless, PMG type: Tewac natural gas pressure inlet to gas compressor: 90 PSIG Scope of supply complete plant with fuel system, water system, cooling tower, liquid fuel tank and pumping system from tanker, ammonia injection system, gas compressor, plant air.

Location: USA

Add to Cart View Details

78000 kW 13800 Volts 60 Hz Combined Cycle Cogeneration Power Plant

78000 kW 13800 Volts 60 Hz Combined Cycle Cogeneration Power Plant

Stock #ZG60451

Used combined cycle cogeneration power plant consisting of (2) GE LM5000 gas fired turbine generators, (2) Deltak HRSG’s and a Elliot steam turbine generator. The LM5000 gas turbine generators both have brush generators rated at 34.8 MVA, .9 power factor, 13.8 KV, 60 Hz, 3600 rpm each. The Elliot steam turbine generator has a brush generator rated at 18.7 MVA, .85 power factor, 13.8 KV, 60 Hz, 3600 rpm. Gas turbine generator #1 package: Stewart & Stevenson turbine manufacturer / OEM: GE aircraft engines model: LM5000-GD-NGA rating: 42024kW time since overhaul: 8716 HRS meter hours: 25,738 hot section hours: 8716 total gt hours: 53,786 fuel: natural gas heat rate: 10,506 BTU/KWH plant: 9075 BTU steam adjusted: 7815 BTU generator: brush model: 61404a-1G frame size: 8DAX 75 - 290E output MVA: 34.8 power factor: 1.0 voltage: 13800 frequency: 60 speed: 3600 specification: ANSI C 50-14 gas turbine generator #2 package: Stewart & Stevenson turbine manufacturer / OEM: GE aircraft engines model: LM5000-GD-NGA rating: 42024kW time since overhaul: 12,270 HRS meter hours: 2,087 hot section hours: 1319 total gt hours: 53,976 fuel: natural gas heat rate: 10,506 BTU/KWH plant: 9075 BTU steam adjusted: 7815 BTU generator: brush model: -34561404a-2G frame size: 8DAX 75-290E output MVA: 34.8 power factor: 1.0 voltage: 13800 frequency: 60 speed: 3600 specification: ANSI C 50-14 Elliot steam turbine generator: model: 2SQNV13 turbine speed: rated: 3600 rpm generator speed: 3600 rpm maximum extraction flow: 150,000 lb/hr rated power: 16,430kW governor: type: Woodward 505E rated inlet pressure: 650PSIG inlet temperature: 675°F extraction pressure: 175PSIG extraction temperature: 473°F exhaust pressure: 2.25"HGA shaft rotation: clockwise viewed from governor end

Location: USA

Add to Cart View Details